No. Foundation vents dilute crawl air a little in mild weather and almost not at all in winter, when stack effect is strongest. The EPA rates natural crawl ventilation far below sub-membrane suction, which is the actual fix.
More detail
The vented crawl is a moisture-era design, and even for moisture it has fallen from favor; for radon it was never a solution. Winter is the season the house pulls hardest on the soil, and it is also when vents move the least useful air while making the floor above cold enough that many owners block them anyway. Opening or closing them mostly rearranges comfort, not radon. Sub-membrane depressurization works in any season because it does not rely on dilution at all: the sealed liner separates the soil surface from the crawl air, and the fan keeps the space under the liner at lower pressure than everything above it. Houses that test high with a vented crawl almost always trace the entry to that bare soil. The EPA's consumer guidance makes the same ranking. See how crawl houses are tested.