Temporarily, yes: dilution works while the windows are open. As a strategy it fails on the first cold night, and reopening a closed house lets levels rebound within hours. It also invalidates any test running at the time.
More detail
Window math collides with the central Indiana calendar. The months when the house pulls hardest on the soil are exactly the months nobody leaves windows open, so the dilution strategy is weakest when exposure is highest. Ventilation does have a legitimate engineered form, heat recovery ventilators that exchange indoor and outdoor air while keeping the heat, and an HRV can trim radon modestly in specific situations, but the EPA classes it as a limited approach next to sub-slab suction, and operating cost scales with airflow. Where open windows genuinely matter is testing protocol: closed-building conditions, 12 hours before and throughout a short test, exist because one open sash can turn a 6 into a 2 and send a family back to not knowing. Fix the pressure problem at the slab and let the windows be windows. See how radon enters.